Cyclone DIESEL3800EU Diesel Engine Belt Driven Air Compressor Diesel Engine Powered Air Compressor for Off-Grid & Remote Outdoor Applications
Engineered for true off-grid independence and reliable performance in remote locations, the Cyclone 100L 6.0HP diesel engine belt driven air compressor eliminates the need for electrical power or batteries. Equipped with a robust 243CC single-cylinder 4-stroke diesel engine and heavy-duty air pump, this unit delivers consistent compressed air for construction sites, road works, mining operations and remote service applications. Backed by strict quality control and durable portable design, it ensures reliable performance even in the most challenging working
Category:
Engine Driven Industrial Air Compressors
Product Details
|
On the technical data plate we will state following information |
|
|
Name |
DIESEL Engine Belt Driven Air Compressor |
|
Cyclone Model NO: |
DIESEL3800EU |
|
Engine Displacement |
243CC(ml) |
|
Engine Bore*stroke |
73*58mm |
|
Engine Max Power |
4.5kw(6.0HP)/3600RPM |
|
Retaed Power |
4. 05KW (5. 5HP)/3600RPM |
|
Engine fuel tank |
2.5L |
|
Max Fuel comsnption |
275g/kw. h (3.5hours ful1 loading) |
|
Lubricated Oil capacity |
0.75L |
|
Engine combustion cycle |
single cyclinder, 4stroke |
|
Start Model |
Hand-operated and Manual |
|
Engine Model NO |
S1731 |
|
Engine Pulley size |
Dia. 110mm*1A |
|
Battery |
NO |
|
Air Pump Bore*stroke |
2*65mm*58mm |
|
Air pump Fly wheels |
350.mm*1A |
|
Compresor Max air delivery |
425L./min |
|
Air delivery @ 90psi |
380L/min |
|
Air delivery @ 116psi |
370L/min |
|
Max working pressure |
8Bar / 0.8Mpa/ 116PSI |
|
Oil&water filter and pressure regulator |
8bar, 3/8"M, brass filter |
|
Cut-In pressure |
6Bar / 0.6Mpa / 90PSI |
|
Pressure controll |
Automatic pressure contronl |
|
Motor Peak Power |
7.0HP/5.2kw Petrol Engine |
|
Tank Capacity |
Ce/ASME Qualified 100Lt Air Tank |
|
Noise (Lwa) |
95dB |
|
N.W/G.W |
90Kgs / 100Kgs. |
|
Packing Size(L+W*H) |
111*42*80CM |
|
Medium |
Nonlethal Compressed Air |
Key Features
● Robust 243CC Diesel Engine: Delivers reliable 6.0HP power output with excellent fuel efficiency, providing up to 3.5 hours of continuous operation on a single 2.5L tank.
● True Off-Grid Independence: No electrical power or batteries required, perfect for remote locations, construction sites and areas without power access.
● Manual Hand-Operated Start: Simple and reliable manual starting system ensures operation even in extreme conditions where batteries would fail.
● 100L CE/ASME Certified Air Tank: Robust thick-gauge steel tank provides sufficient air reserve for continuous outdoor operation.
● High-Efficiency Air Pump: Delivers up to 425L/min max airflow, suitable for impact wrenches, jackhammers and other heavy-duty pneumatic tools.
● Brass Oil&Water Filter & Regulator: High-quality brass components ensure long service life and clean, regulated compressed air output.
● Portable Heavy-Duty Design: Fitted with durable wheels and reinforced frame for easy transport over rough terrain and uneven surfaces.
Expert Advice
● Daily Tank Drainage: Always drain condensed moisture from the 100L tank after each use to prevent internal corrosion and ensure air quality.
● Fuel Safety: Use only clean, fresh diesel fuel; never use petrol or contaminated fuel. Store fuel in approved containers away from heat sources.
● Winter Operation: In cold temperatures, use winter-grade diesel fuel to prevent fuel gelling; allow the engine to warm up before applying load.
● Engine Oil Maintenance: Check engine oil level (0.75L capacity) before each use; change oil every 50 hours of operation or as recommended.
● Air Filter Care: Clean or replace the engine and pump air filters regularly, especially in dusty environments, to prevent engine damage.
● Exhaust Safety: Never operate the compressor indoors or in enclosed spaces; diesel exhaust contains harmful carbon monoxide.
● Cooling & Ventilation: Operate in a well-ventilated area away from flammable materials; allow the engine to cool before refueling.
Troubleshooting Guide
|
Problem |
Possible Cause |
Recommended Solution |
|
Compressor fails to start |
1. No fuel in diesel tank 2. Stale or contaminated fuel 3. Air in fuel system 4. Glow plug not working (if equipped)5. Incorrect starting procedure |
1. Fill tank with fresh diesel fuel 2. Drain old fuel and replace with fresh fuel 3. Bleed air from fuel system using the primer pump 4. Test and replace glow plug if defective 5. Follow the correct manual starting procedure |
|
Engine runs but pump does not operate |
1. Loose or broken drive belt 2. Misaligned pulleys 3. Jammed or seized pump mechanism |
1. Inspect, adjust or replace the drive belt 2. Align engine and pump pulleys to correct position 3. Disassemble the pump to remove debris or obstructions |
|
Pressure builds too slowly or fails to reach rated pressure |
1. Air leaks in hoses, fittings, check valve or tank 2. Worn piston rings, valves or seals in the pump 3. Clogged air intake filter 4. Engine running at low speed |
1. Perform leak test with soapy water; tighten connections or replace faulty parts 2. Inspect and replace worn pump components 3. Clean or replace the air filter 4. Adjust engine throttle to correct operating speed |
|
Excessive noise, vibration or unusual rattling |
1. Loose mounting bolts, fasteners or engine components 2. Worn engine or pump bearings 3. Damaged or unbalanced flywheel 4. Unit placed on an uneven or unstable surface |
1. Tighten all bolts and fasteners securely, including engine mounts 2. Inspect and replace worn bearings 3. Service or replace damaged flywheel if out of balance 4. Position the compressor on a flat, level and stable surface |
|
Engine overheats or shuts down prematurely |
1. Low engine oil level 2. Clogged engine cooling fins or air filter 3. Continuous operation beyond rated duty cycle 4. Operating in excessively hot environment |
1. Check and top up engine oil to correct level 2. Clean cooling fins and replace air filter 3. Allow sufficient cooling breaks between runs 4. Move to a shaded, well-ventilated area |
|
Air pressure drops significantly under load |
1. Undersized, kinked or damaged air hoses 2. Incorrectly adjusted or faulty pressure regulator 3. Leaking check valve in the tank 4. Excessive air consumption from connected tools |
1. Replace with correct diameter hoses, remove kinks and repair leaks 2. Calibrate or replace the pressure regulator 3. Inspect, clean or replace the check valve 4. Ensure total air consumption does not exceed 425L/min |
FAQs
▼ What size air compressor do I need?
The right compressor depends on your CFM requirements. For remote construction, road works, mining operations and off-grid applications, the Cyclone DIESEL3800EU 100L 6.0HP diesel model provides true independence and sufficient airflow for most heavy-duty pneumatic tools.
▼ How often must I drain an air compressor?
Drain the tank daily after every use, or more frequently in humid environments, to prevent internal corrosion and water contamination.
▼ What oil do I use in my air compressor?
Use professional compressor-grade non-detergent oil for the air pump. For the diesel engine, use the recommended 4-stroke diesel engine oil as specified in the engine manual.
▼ Can I use this compressor indoors?
This diesel engine compressor produces harmful exhaust fumes and should never be used indoors, in enclosed spaces or near flammable materials. Always operate outdoors in a well-ventilated area.
▼ What size air hose should I use?
For outdoor applications with this diesel compressor, a 3/8" (10mm) or 1/2" (13mm) diameter hose is recommended to avoid pressure drop and ensure efficient airflow.
Previous page
Next page
Previous page
Next page