Cyclone V-707HEU Two-Stage, Big Air Delivery, Industrial Belt-Driven Compressor Heavy-Duty Two-Stage High-Pressure Industrial Belt-Driven Air Compressor | 500L Large-Capacity Wheeled Horizontal Tank & Stable Continuous Industrial Operation
Engineered for heavy-duty continuous industrial compressed air applications requiring high-pressure and large-volume airflow, the Cyclone V-707HEU two-stage air compressor features a robust two-stage cast-iron pump head, industrial-grade 10HP motor, heavy-duty belt-driven transmission system and a massive 500L CE/ASME certified air tank. Optimized for 380-400V three-phase power supply, it delivers ultra-large air delivery and stable high-pressure performance. Ideal for heavy-duty manufacturing plants, large auto repair workshops, construction engineering, sandblasting and continuous industrial production lines, providing high-pressure, large-flow, long-life stable compressed air with industrial-grade reliability.
Category:
Belt Driven Compressors-(Japan/USA Style Casting iron Air Pump)
Product Details
|
On the technical data plate we will state following information |
|
|
Name |
Two stage,Big Air Delivery, Industrial Belt Driven Compressor |
|
Cyclone Model NO: |
V-707HEU |
|
Motor Peak Power |
7.5KW/10HP |
|
Input Voltage: |
380-400V/50HZ |
|
Max Air Delivery |
1229L/min |
|
Air Delivery@ 60Psi |
975L/min |
|
Air Delivery@ 90PSI |
928L/min |
|
Shaft Rated Speed |
670 r.p.m |
|
Air Pump Piston Size |
2*Dia.105mm +55mm |
|
Stroke Length |
89mm |
|
Pump Flywheels |
480mm |
|
Motor pulley size |
220mm |
|
Pump Lubricate Oil capacity |
1.6L |
|
Rated Electric Current |
15.0A |
|
Overload Current Protector |
18.0A |
|
Startig Capacity |
300V with 20M power cable |
|
Max working pressure |
12Bar /1.2Mpa / 175PSI |
|
Cut-In pressure |
9Bar / 0.9Mpa / 130PSI |
|
Tank Capacity |
Ce/ASME Qualified 500Lt Air Tank |
|
Noise (Lwa) |
97dB |
|
N.W/G.W |
345Kgs / 400Kgs. |
|
Packing Size(L+W*H) |
195*65*125CM |
|
Medium |
Nonlethal Compressed Air |
Key Features
● Two-Stage High-Pressure Industrial Pump Head: Heavy-duty two-stage cast-iron pump structure with large-size pistons and long-stroke design, realizing high-pressure compression up to 12Bar, with strong air displacement and stable performance for heavy-duty industrial continuous operation.
● Ultra-Large Air Delivery Performance: Max air delivery reaches 1229L/min, with stable output at 60PSI and 90PSI working conditions, meeting large-flow multi-tool simultaneous industrial use demands.
● Industrial-Grade Belt-Driven Transmission System: Large-size 480mm flywheel and 220mm motor pulley, low-speed 670r.p.m rated shaft speed, stable torque output, low motor load, wear-resistant and long service life.
● Professional Electrical Safety Configuration: Matched with 15.0A rated current and 18.0A overload protection, 300V starting capacity supporting 20-meter long-distance power cable start-up, adapting to complex industrial power supply environments.
● Large-Capacity 500L Pressure Vessel: CE/ASME certified heavy-duty air tank, large gas storage capacity, reducing frequent start-stop of the unit, extending continuous working time.
● Heavy-Duty Robust Structure: Thickened steel body, heavy-duty wheeled base, suitable for harsh factory and construction site environments, strong impact resistance and durability.
● Complete Cooling & Lubrication System: 1.6L large-capacity pump lubricating oil design, with independent large-area cooling net, efficient heat dissipation during long-time full-load operation.
● Dual-Pressure Automatic Control: Automatic cut-in pressure at 9Bar, automatic stop at 12Bar, realizing intelligent automatic pressure control.
Expert Advice
● Daily Maintenance: Check pump lubricating oil level regularly, maintain oil volume at 1.2-1.6L; replace special air compressor oil every 500-800 working hours; clean cooling net and air intake filter weekly.
● Pressure Operation: Factory preset cut-in pressure 9Bar, max working pressure 12Bar; do not adjust pressure switch to exceed factory settings to avoid overload damage.
● Power Supply Requirements: Must use 380-400V three-phase stable power supply; for power cables longer than 20 meters, use thicker-diameter cables to ensure starting voltage stability.
● Operating Environment: Use in well-ventilated open-air or semi-open industrial areas; avoid high-temperature, dusty and humid closed environments.
● Belt Inspection: Check belt tension and wear monthly; adjust tension in time, replace worn belts to prevent slipping and power loss.
● Condensate Drainage: Drain condensed water from the tank bottom drain valve every 2-4 hours during continuous heavy-duty operation to prevent internal corrosion of the air tank.
● Duty Cycle & Cooling: Under full-load 12Bar high-pressure mode, allow a 15-minute cooling break after every 40 minutes of continuous operation to protect pump and motor.
● Mobility Safety: Depressurize the tank below 1Bar before moving; ensure the ground is flat and stable during transportation.
● Storage Guidelines: Depressurize the tank completely, drain all moisture, clean pump and cooling net, store in a dry, dust-free and well-ventilated warehouse.
Troubleshooting Guide
|
Problem |
Possible Cause |
Recommended Solution |
|
Compressor fails to start |
1. Three-phase power phase loss or unstable voltage 2. Overload protector tripped3. Faulty pressure switch 4. Motor thermal overload protection triggered |
1. Check three-phase power supply and cable connection 2. Reset overload current protector 3. Inspect and replace faulty pressure switch4. Let motor cool completely before restarting |
|
Belt slips or makes abnormal noise |
1. Insufficient belt tension 2. Worn aging belt 3. Dirty or damaged flywheel/pulley surface |
1. Adjust motor position to increase belt tension 2. Replace heavy-duty industrial belt 3. Clean flywheel surface or repair damaged pulley |
|
Slow pressure build-up / insufficient air flow |
1. Air leaks in pipelines, joints or check valve 2. Clogged air intake filter or valve plate damage 3. Worn piston rings of two-stage pump |
1. Test leaks with soapy water and repair all air-leaking points 2. Clean or replace intake filter, inspect and replace damaged valve plates 3. Replace worn piston rings and maintain pump sealing performance |
|
Abnormal pump vibration / heavy noise |
1. Loose mounting screws of pump and motor 2. Unbalanced flywheel 3. Insufficient lubricating oil or damaged bearings |
1. Tighten all mounting fasteners 2. Re-balance or replace unbalanced flywheel 3. Refill specified air compressor oil or replace damaged bearings |
|
Motor overheats and shuts off |
1. Long-time full-load continuous operation 2. Blocked cooling net leading to poor heat dissipation 3. Over-tightened belt causing excessive motor load |
1. Strictly follow recommended duty cycle 2. Clear dust from cooling net and improve ventilation 3. Adjust belt tension to standard level |
|
Pressure drops sharply under heavy load |
1. Kinked or undersized industrial air hoses 2. Faulty pressure regulator 3. Leaking air tank check valve |
1. Replace with large-diameter heavy-duty industrial air hoses 2. Calibrate or replace pressure regulator 3. Inspect and replace leaking check valve |
FAQs
▼ What are the advantages of two-stage high-pressure design?
Two-stage compression realizes high-pressure output up to 12Bar, with larger air delivery and higher compression efficiency, suitable for high-pressure industrial applications such as sandblasting and high-pressure pneumatic tools.
▼ What scenarios is this industrial compressor suitable for?
Ideal for heavy-duty manufacturing factories, large auto repair workshops, engineering construction, sandblasting rust removal, mining auxiliary equipment, and continuous multi-tool industrial production lines.
▼ Why does it support 20-meter long-distance power cable start-up?
Equipped with 300V high starting capacity, it can adapt to long-distance power supply in large factories and construction sites, avoiding starting failure caused by voltage drop.
▼ What is the service life of this heavy-duty unit?
Industrial-grade cast-iron pump head + heavy-duty transmission structure, with standardized maintenance, the service life can reach 8-12 years, suitable for long-term continuous production.
▼ What safety standards does the tank meet?
The 500L large-capacity air tank is CE/ASME certified, complying with international pressure vessel safety standards for global industrial market access