Cyclone V3050SEU Oil-Lubricated Professional Direct Driven Compressor High-Power Dual-Cylinder Direct Driven Air Compressor with Dual Pressure & Dual Frequency Capabilities
Engineered for versatile professional performance, the Cyclone V3050SEU oil-lubricated direct driven compressor combines a robust 3.0HP motor with a precision dual-cylinder pump, delivering exceptional airflow with dual working pressure options and global dual frequency compatibility. This unit is purpose-built for automotive repair shops, small manufacturing facilities, construction sites and continuous-use pneumatic tool operations, offering unmatched flexibility for diverse professional applications. Backed by Cyclone's stringent manufacturing standards, it ensures reliable long-term operation even under demanding working conditions.
Category:
Direct Link Air Compressors
Product Details
|
On the technical data plate we will state following information |
|
|
Name |
Oil-Lubricated Professional Direct Driven Compressor |
|
Cyclone Model NO: |
V3050SEU |
|
Motor Peak Power: |
2.2KW/3.0HP |
|
Input Voltage: |
220-240V |
|
Air Delivery@50HZ |
300L/min |
|
Air Delivery@60HZ |
360L/min |
|
Pump Shaft Rated Speed@50HZ |
2850r.p.m |
|
Pump Shaft Rated Speed@60HZ |
3450r.p.m |
|
Piston Size |
2*Dia.42mm |
|
Stroke size |
38mm |
|
Max working pressure |
8Bar /0.8Mpa/116PSI 10Bar/1Mpa/145PSI |
|
Tank Capacity |
Ce/ASME Qualified 50Lt Air Tank |
|
Medium |
Nonlethal Compressed Air |
Key Features
● Industrial-Grade 3.0HP High-Torque Motor: Delivers 2.2KW (3.0HP) peak power output, providing strong starting torque and stable performance under continuous medium-duty load conditions.
● High-Efficiency Dual-Cylinder Pump: Features a precision-engineered dual-cylinder design with 2*Dia.42mm piston size and 38mm stroke length, optimized for balanced air compression efficiency and high-volume output.
● Global Dual Frequency Compatibility: Automatically adapts to both 50HZ and 60HZ power grids, delivering 300L/min @ 50HZ and 360L/min @ 60HZ air delivery for worldwide professional applications.
● Dual Working Pressure Options: Supports both 8Bar (116PSI) and 10Bar (145PSI) maximum working pressures, adapting to a wide range of pneumatic tool requirements from light to heavy-duty applications.
● 50L Large-Capacity Air Tank: CE/ASME certified thick-gauge steel tank provides extended air reserve, reducing frequent motor startups and extending component service life.
● Maintenance-Free Direct Drive System: Eliminates belt slip, adjustment and replacement requirements, delivering up to 95% energy efficiency and more reliable power transfer than traditional belt-driven models.
● Optimized Variable Speed Operation: Operates at 2850r.p.m @ 50HZ and 3450r.p.m @ 60HZ, perfectly balanced for efficient air compression, low vibration and reliable continuous operation.
● International Safety Certification: 50L thick-gauge steel air tank with CE/ASME certification, ensuring safe and stable pressure retention under all operating conditions.
Expert Advice
● Daily Tank Maintenance: Always drain condensed moisture from the 50L air tank immediately after each use, especially in humid environments, to prevent internal corrosion and ensure the purity of compressed air.
● Dual Pressure Operation: Select the appropriate working pressure (8Bar or 10Bar) according to the specific requirements of your pneumatic tools. Using higher pressure than necessary will increase energy consumption and component wear.
● Lubrication Management: Check the pump lubricating oil level before each startup. Replace the pump oil every 300 operating hours or as recommended in the product manual to maintain optimal pump performance and prevent premature wear.
● Power Supply Compatibility: This compressor supports both 50HZ and 60HZ power supplies within the 220-240V input voltage range. Ensure the power supply matches your local grid specifications before use.
● Duty Cycle Compliance: Avoid continuous operation beyond the rated duty cycle to prevent motor overheating. Allow a 10-minute cooling break after every 30 minutes of continuous operation.
● Pressure Safety Regulation: Never exceed the maximum working pressure of 10Bar (145PSI). Adjust the pressure regulator precisely to match your tool's requirements for optimal efficiency and safety.
● Proper Storage Guidelines: When storing the compressor for extended periods, drain all moisture from the 50L air tank and top up the pump lubricating oil. Store in a dry, well-ventilated area away from direct sunlight and corrosive substances.
Troubleshooting Guide
|
Problem |
Possible Cause |
Recommended Solution |
|
Compressor fails to start |
1. No power supply or damaged power cord 2. Blown fuse or tripped circuit breaker 3. Faulty pressure switch 4. Motor overload protection activated |
1. Check power connection and inspect cord for damage 2. Reset circuit breaker or replace fuse with correct rating 3. Test and replace faulty pressure switch 4. Allow motor to cool completely for 30 minutes before restarting |
|
Pressure builds too slowly or fails to reach 10Bar |
1. Air leaks in hoses, fittings, check valve or tank 2. Worn piston rings or valves in the dual-cylinder pump 3. Clogged air intake filter 4. Pump shaft speed below rated value |
1. Perform a leak test with soapy water and repair all leaks 2. Inspect and replace worn pump piston rings or valves 3. Clean or replace the air intake filter 4. Verify power supply frequency matches the rated speed |
|
Motor runs but no air pressure |
1. Broken intake or exhaust valve in the pump 2. Seized pump mechanism due to insufficient lubrication 3. Damaged pump shaft or bearings 4. Leaking check valve in the 50L tank |
1. Inspect and replace faulty intake/exhaust valves 2. Check pump lubricating oil level and top up if necessary 3. Repair or replace damaged pump components 4. Inspect, clean or replace the leaking check valve |
|
Excessive noise or vibration |
1. Loose mounting bolts or fasteners 2. Worn motor or pump bearings 3. Unbalanced motor shaft 4. Uneven placement surface 5. Low pump lubricating oil level |
1. Tighten all bolts and fasteners securely 2. Replace worn motor or pump bearings 3. Service or replace unbalanced motor shaft 4. Place compressor on a flat, stable surface 5. Top up pump lubricating oil to the recommended level |
|
Motor overheats |
1. Continuous overload operation beyond duty cycle 2. Clogged motor cooling vents 3. Poor ventilation in operating area 4. Low pump lubricating oil level 5. Power supply voltage outside 220-240V range |
1. Allow sufficient cooling breaks between operation cycles 2. Clear all obstructions from motor cooling vents 3. Move compressor to a well-ventilated area 4. Top up pump lubricating oil 5. Ensure power supply voltage is within specified range |
|
Air pressure drops significantly under load |
1. Undersized, kinked or damaged air hoses 2. Faulty pressure regulator 3. Leaking check valve in the 50L tank 4. Total air consumption exceeds compressor capacity 5. Worn pump piston rings or valves |
1. Replace with appropriate diameter hoses and remove kinks 2. Calibrate or replace the faulty pressure regulator 3. Inspect and replace the check valve 4. Reduce the number of simultaneously operating tools 5. Inspect and replace worn pump components |
FAQs
▼ What applications is this compressor suitable for?
The Cyclone V3050SEU 50L 3.0HP oil-lubricated direct driven compressor is ideal for automotive repair shops, small manufacturing facilities, construction sites and medium-to-heavy duty pneumatic tool operations including impact wrenches, spray guns, nail guns and air ratchets.
▼ What is the maximum air delivery of this compressor?
The maximum air delivery is 300L/min @ 50HZ and 360L/min @ 60HZ, providing sufficient airflow for most medium-duty professional applications.
▼ What working pressures does this compressor support?
This compressor supports dual working pressure options: 8Bar / 0.8Mpa / 116PSI and 10Bar / 1Mpa / 145PSI, adapting to a wide range of pneumatic tool requirements.
▼ Does this compressor support both 50HZ and 60HZ power supplies?
Yes, this compressor features automatic dual frequency adaptation, operating seamlessly on both 50HZ and 60HZ power supplies within the 220-240V input voltage range for global use.
▼ What is the pump shaft rated speed?
The pump shaft rated speed is 2850r.p.m @ 50HZ and 3450r.p.m @ 60HZ, optimized for maximum air compression efficiency and long component service life.
Keywords: