Cyclone W‑1.0EU Casting Iron Pump Professional Belt‑Driven Air Compressor Single‑Motor Heavy‑Duty Triple‑Piston Cast‑Iron Industrial Belt‑Driven Air Compressor | 300L Wheeled Horizontal Tank & Dual‑Pressure Industrial Operation
Engineered for heavy‑duty large‑flow continuous industrial compressed‑air applications, the Cyclone W‑1.0EU belt‑driven air compressor features a heavy‑duty triple‑piston cast‑iron pump head, professional belt‑drive transmission system, single industrial‑grade 10HP motor and a large‑capacity 300L CE/ASME certified air tank. Powered by stable 380‑400V three‑phase industrial power supply, it delivers high‑volume airflow with dual‑pressure working capability. Ideal for manufacturing plants, auto repair centers, large carpentry workshops, construction engineering and heavy‑duty multi‑tool operation, providing reliable, large‑flow, long‑life stable compressed air with industrial‑grade durability.
Category:
Belt Driven Compressors-(Japan/USA Style Casting iron Air Pump)
Product Details
|
On the technical data plate we will state following information |
|
|
Name |
Casting Iron Pump Professional Belt Driven Air Compressor |
|
Cyclone Model NO: |
W-1.0EU |
|
Motor Peak Power |
7.5KW/10HP |
|
Input Voltage: |
380-400V |
|
Air Delivery |
980L/min |
|
pump flywheel size |
Dia.370mm(AL) |
|
motor pulley size |
Dia.110mm(Fe) |
|
Piston Size |
3*Dia.90mm |
|
Stroke Length |
60mm |
|
working pressure |
8Bar /0.8Mpa/116PSI 10Bar/1Mpa/145PSI |
|
Tank Capacity |
Ce/ASME Qualified 300Lt Air Tank |
|
Medium |
Nonlethal Compressed Air |
Key Features
● Triple-Piston Heavy-Duty Cast-Iron Pump Head: High-strength triple-piston cast-iron pump body with large-size Dia.90mm pistons and long 60mm stroke, thick-wall cylinders and reinforced crankshaft, wear-resistant, high-temperature resistant and stable for long-hour continuous industrial operation.
● Professional Heavy-Duty Belt-Driven Transmission: Large-size 370mm aluminum flywheel and 110mm iron motor pulley, stable high-torque output, low motor load, smoother operation and longer service life under heavy-duty conditions.
● Ultra-Large-Flow Air Output: Air delivery reaches 980L/min, meeting high-demand multi-tool simultaneous operation requirements for industrial production lines.
● Dual-Pressure Working Mode: Supports standard 8Bar and high-pressure 10Bar modes, adaptable to various pneumatic tools, painting and industrial equipment needs.
● Three-Phase Industrial Power Supply: Optimized for 380-400V three-phase power supply, stable power output, strong overload resistance, suitable for long-time non-stop factory operation.
● Large-Capacity 300L Pressure Vessel: CE/ASME certified heavy-duty air tank with massive gas storage capacity, reducing frequent start-stop cycles and extending continuous working time.
● Robust Industrial Structure: Thickened steel body and heavy-duty wheeled base, adapting to harsh factory and construction-site environments with strong impact resistance and durability.
● High-Efficiency Cooling System: Large-area fin-type heat-dissipation structure and cooling fan, ensuring efficient heat removal during long-time full-load operation.
Expert Advice
● Daily Maintenance: Check pump lubricating oil level regularly; replace special air-compressor oil every 500-800 working hours; clean cooling net and air intake filter weekly.
● Pressure Operation: Standard working pressure is 8Bar for daily use; 10Bar high-pressure mode only for special heavy-duty tools. Do not exceed factory-set pressure limits.
● Power Supply Requirements: Must use stable 380-400V three-phase industrial power supply with standard-gauge power cables to ensure stable heavy-duty start-up and operation.
● Operating Environment: Use in well-ventilated open-air or semi-open industrial areas; avoid high-temperature, dusty and humid closed environments.
● Belt Inspection: Check belt tension and wear monthly; adjust tension in time and replace worn belts to prevent slipping and power loss.
● Condensate Drainage: Drain condensed water from the tank bottom drain valve every 2-4 hours during continuous heavy-duty operation to prevent internal corrosion of the air tank.
● Duty Cycle & Cooling: Under full-load operation, allow a 10-minute cooling break after every 30 minutes of continuous work to protect pump and motor.
● Mobility Safety: Depressurize the tank below 1Bar before moving; ensure the ground is flat and stable during transportation.
● Storage Guidelines: Depressurize the tank completely, drain all moisture, clean pump unit and cooling system, store in a dry, dust-free and well-ventilated warehouse.
Troubleshooting Guide
|
Problem |
Possible Cause |
Recommended Solution |
|
Compressor fails to start |
1. Three-phase power phase loss or unstable voltage 2. Overload protection triggered 3. Faulty pressure switch 4. Motor thermal overload protection triggered |
1. Check three-phase power supply and cable connections 2. Reset overload protector 3. Inspect and replace faulty pressure switch 4. Let motor cool completely before restarting |
|
Belt slips or makes abnormal noise |
1. Insufficient belt tension 2. Worn aging belt 3. Dirty or damaged flywheel/pulley surface |
1. Adjust motor position to increase belt tension 2. Replace heavy-duty industrial belt 3. Clean flywheel surface or repair damaged pulley |
|
Slow pressure build-up / insufficient air flow |
1. Air leaks in pipelines, joints or check valve 2. Clogged air intake filter or valve-plate damage 3. Worn piston rings of cast-iron pump |
1. Test leaks with soapy water and repair all air-leaking points 2. Clean or replace intake filter, inspect and replace damaged valve plates 3. Replace worn piston rings and maintain pump sealing performance |
|
Abnormal pump vibration / heavy noise |
1. Loose mounting screws of pump and motor 2. Unbalanced flywheel 3. Insufficient lubricating oil or damaged bearings |
1. Tighten all mounting fasteners 2. Re-balance or replace unbalanced flywheel 3. Refill specified air-compressor oil or replace damaged bearings |
|
Motor overheats and shuts off |
1. Long-time full-load continuous operation 2. Blocked cooling net leading to poor heat dissipation 3. Over-tightened belt causing excessive motor load |
1. Strictly follow recommended duty cycle 2. Clear dust from cooling net and improve ventilation 3. Adjust belt tension to standard level |
|
Pressure drops sharply under heavy load |
1. Kinked or undersized industrial air hoses 2. Faulty pressure regulator 3. Leaking air-tank check valve |
1. Replace with large-diameter heavy-duty industrial air hoses 2. Calibrate or replace pressure regulator 3. Inspect and replace leaking check valve |
FAQs
▼ What are the advantages of triple‑piston cast‑iron design?
Triple‑piston layout ensures stable compression efficiency; cast‑iron pump head features high hardness, wear resistance and heat resistance, suitable for long‑time continuous industrial work.
▼ What scenarios is this industrial compressor suitable for?
Ideal for manufacturing factories, auto repair centers, large carpentry workshops, engineering construction, hardware processing, and multi‑tool industrial production lines.
▼ What is the difference between 8Bar and 10Bar working pressure?
8Bar is standard daily‑use pressure for most pneumatic tools; 10Bar is high‑pressure mode for special heavy‑duty equipment, with shorter continuous working time under 10Bar mode.
▼ Why use aluminum flywheel for this model?
Aluminum flywheel has lighter weight and better dynamic balance, reducing motor starting load and vibration during high‑speed operation, improving overall stability and service life.
▼ What safety standards does the tank meet?
The 300L large‑capacity air tank is CE/ASME certified, complying with international pressure‑vessel safety standards for global industrial market access.
Keywords:
Previous page
Next page
Previous page
Next page