Cyclone Z-0.17EU Aluminium alloy Monoblock Professional Air Compressor High-Efficiency Dual-Cylinder Aluminium Alloy Monoblock Air Compressor with Dual Pressure Options Workshop & Professional Use Professional Workshop Applications
Engineered for superior performance and durability in professional working environments, the Cyclone Z-0.17EU aluminium alloy monoblock professional air compressor features a lightweight high-strength aluminium alloy monoblock pump and robust dual-cylinder design, delivering consistent high-volume compressed air with dual working pressure options. This unit is purpose-built for professional workshops, automotive repair facilities, construction sites and various pneumatic tool applications, combining excellent heat dissipation, low vibration and long service life. Backed by Cyclone's stringent manufacturing standards, it ensures reliable performance even under continuous operating conditions.
Category:
Belt Driven Compressors-(Italy Style Mono block Air Pump)
Product Details
|
On the technical data plate we will state following information |
|
|
Name |
Aluminium alloy Monoblock Professional Air Compressor |
|
Cyclone Model NO: |
Z-0.17EU |
|
Motor Peak Power |
1.5KW/2.0HP |
|
Input Voltage: |
220-240V |
|
Air Delivery |
222L/min |
|
Pump Shaft Rated Speed |
1090R.P.M |
|
Piston Size |
2*Dia.60mm |
|
Stroke size |
36mm |
|
working pressure |
8Bar /0.8Mpa/116PSI 10Bar/1Mpa/145PSI |
|
Tank Capacity |
Ce/ASME Qualified 50Lt Air Tank |
|
Medium |
Nonlethal Compressed Air |
Key Features
● High-Strength Aluminium Alloy Monoblock Pump: Adopts integrated aluminium alloy monoblock construction, providing excellent heat dissipation, lightweight design and superior structural rigidity, significantly extending pump service life.
● Powerful Dual-Cylinder Design: Features 2*Dia.60mm piston size with 36mm stroke length, delivering a stable 222L/min air delivery for efficient and continuous compressed air supply.
● Dual Working Pressure Options: Supports both 8Bar (116PSI) and 10Bar (145PSI) maximum working pressures, adapting to a wide range of pneumatic tool requirements from light to medium-duty applications.
● Optimized Low-Speed Operation: Operates at a rated pump shaft speed of 1090R.P.M, reducing component wear, lowering vibration and extending the service life of critical moving parts.
● 1.5KW High-Torque Motor: Delivers 2.0HP peak power output, providing strong starting torque and stable performance under continuous load conditions.
● 50L Certified Air Tank: CE/ASME qualified thick-gauge steel air tank provides sufficient air reserve, reducing frequent motor startups and ensuring stable pressure output.
● Global Voltage Compatibility: Supports 220-240V input voltage, making it suitable for use in most countries and regions worldwide.
Expert Advice
● Daily Tank Maintenance: Always drain condensed moisture from the 50L air tank immediately after each use, especially in humid environments, to prevent internal corrosion and ensure compressed air quality.
● Dual Pressure Operation: Select the appropriate working pressure (8Bar or 10Bar) according to the specific requirements of your pneumatic tools. Using higher pressure than necessary will increase energy consumption and component wear.
● Lubrication Management: Regularly check the pump lubricating oil level and replace oil according to the maintenance schedule. Proper lubrication is essential for the aluminium alloy monoblock pump's performance and longevity.
● Pressure Regulation: Never exceed the maximum working pressure of 10Bar (145PSI). Adjust the pressure regulator precisely to match your tool's requirements for optimal efficiency and safety.
● Pump Maintenance: The aluminium alloy monoblock design requires minimal maintenance, but regular inspection of piston rings and valves is recommended to maintain optimal air delivery performance.
● Storage Guidelines: When storing for extended periods, drain all moisture from the 50L air tank and top up the pump lubricating oil. Store in a dry, well-ventilated area away from direct sunlight and corrosive substances.
Troubleshooting Guide
|
Problem |
Possible Cause |
Recommended Solution |
|
Compressor fails to start |
1. No power supply or damaged power cord 2. Blown fuse or tripped circuit breaker 3. Faulty pressure switch 4. Motor overload protection activated |
1. Check power connection and inspect cord for damage 2. Reset circuit breaker or replace fuse with correct rating 3. Test and replace faulty pressure switch 4. Allow motor to cool completely before restarting |
|
Pressure builds too slowly or fails to reach 10Bar |
1. Air leaks in hoses, fittings, check valve or tank 2. Worn piston rings or valves in the dual-cylinder pump 3. Clogged air intake filter 4. Pump shaft speed below 1090R.P.M |
1. Perform a leak test with soapy water and repair all leaks 2. Inspect and replace worn pump components 3. Clean or replace the air intake filter 4. Check motor operation and power supply voltage |
|
Motor runs but no air pressure |
1. Broken intake or exhaust valve in the pump 2. Seized pump mechanism due to insufficient lubrication 3. Damaged pump shaft or bearings 4. Leaking check valve in the 50L tank |
1. Inspect and replace faulty intake/exhaust valves 2. Check pump lubricating oil level and top up if necessary 3. Repair or replace damaged pump components 4. Inspect, clean or replace the leaking check valve |
|
Excessive noise or vibration |
1. Loose mounting bolts or fasteners 2. Worn motor or pump bearings 3. Unbalanced rotating components 4. Uneven placement surface 5. Low pump lubricating oil level |
1. Tighten all bolts and fasteners securely 2. Replace worn bearings 3. Service or replace unbalanced components 4. Place compressor on a flat, stable surface 5. Top up pump lubricating oil to recommended level |
|
Motor overheats |
1. Continuous overload operation beyond duty cycle 2. Clogged motor cooling vents 3. Poor ventilation in operating area 4. Low pump lubricating oil level 5. Power supply voltage outside 220-240V range |
1. Allow sufficient cooling breaks between operation cycles 2. Clear all obstructions from motor cooling vents 3. Move compressor to a well-ventilated area 4. Top up pump lubricating oil 5. Ensure power supply voltage is within specified range |
|
Air pressure drops significantly under load |
1. Undersized, kinked or damaged air hoses 2. Faulty pressure regulator 3. Leaking check valve in the 50L tank 4. Total air consumption exceeds 222L/min 5. Worn pump piston rings or valves |
1. Replace with appropriate diameter hoses and remove kinks 2. Calibrate or replace the faulty pressure regulator 3. Inspect and replace the check valve 4. Reduce the number of simultaneously operating tools 5. Inspect and replace worn pump components |
FAQs
▼ What applications is this compressor suitable for?
The Cyclone Z-0.17EU 50L 2.0HP aluminium alloy monoblock compressor is ideal for professional workshops, automotive repair facilities, construction sites and various pneumatic tool operations including nail guns, spray guns, impact wrenches and air ratchets.
▼ What is the air delivery of this compressor?
The compressor delivers a stable 222L/min air delivery, providing sufficient airflow for most medium-duty professional applications.
▼ What working pressures does this compressor support?
This compressor supports dual working pressure options: 8Bar / 0.8Mpa / 116PSI and 10Bar / 1Mpa / 145PSI, adapting to a wide range of pneumatic tool requirements.
▼ What is the pump shaft rated speed?
The pump shaft rated speed is 1090R.P.M, optimized for low wear, low vibration and long component service life.
▼ What are the advantages of the aluminium alloy monoblock pump?
The aluminium alloy monoblock pump provides excellent heat dissipation, lightweight design, superior structural rigidity and reduced vibration, significantly extending the service life of the compressor.
Keywords:
Previous page
Next page
Previous page
Next page