Cyclone Z-0.60EU Belt-Driven Air Compressor Industrial Heavy-Duty High Pressure Air Compressor for Professional Workshop Applications
Built for demanding industrial environments, the Cyclone 300L 4.30kW (6.0HP) belt-driven air compressor delivers high-volume, reliable compressed air for continuous heavy-duty use. Featuring a robust cast-iron pump, oversized flywheel and 300L CE/ASME certified air tank, this 300-400V unit is designed for workshops, garages and industrial settings where consistent, high-pressure performance is critical. Backed by our in-house manufacturing and strict quality control, it’s the ultimate workhorse for professional-grade pneumatic tools and multi-station setups.
Category:
Belt Driven Compressors-(Italy Style Mono block Air Pump)
Product Details
|
On the technical data plate we will state following information |
|
|
Name |
Big Air Delivery,High pressure Industrial Belt Driven Compressorr |
|
Cyclone Model NO: |
Z-0.60EU |
|
Motor Peak Power |
4.30KW/6.0HP |
|
Input Voltage: |
300-400V/50HZ |
|
Max Air Delivery |
700L/min |
|
Air Delivery@90Psi |
638L/min |
|
Air Delivery@145PSI |
600L/min |
|
Pump Shaft Rated Speed |
920R.P.M |
|
Air Pump Bore / Piston Size |
90mm*2 |
|
Stroke Length |
60mm |
|
Pump Flywheels |
400mm |
|
Motor pulley size |
130mm |
|
Pump Lubricate Oil capacity |
1.0L |
|
Rated Electric Current |
9.0A |
|
Overload Current Protector |
10.0A |
|
Startig Capacity |
300V,with 20M power calbe |
|
Max working pressure |
8Bar/ 0.8Mpa / 116PSI |
|
Cut-In pressure |
6Bar / 0.6Mpa/ 90PSI |
|
Motor Peak Power |
4.30KW/6.0HP |
|
Tank Capacity |
Ce/ASME Qualified 300Lt Air Tank |
|
Noise (Lwa) |
95dB |
|
N.W/G.W |
166Kgs/200kgs |
|
Packing Size(L+W*H) |
162*56*108CM |
|
Medium |
Nonlethal Compressed Air |
Key Features
● Industrial-Grade Belt-Driven Cast Iron Pump: 6.0HP motor paired with a heavy-duty two-stage pump and 400mm flywheel delivers powerful, low-vibration airflow with extended service life.
● 300L CE/ASME Certified Air Tank: Oversized thick-gauge steel tank with superior pressure retention, designed for long continuous operation and minimal pressure drops.
● High-Volume Air Delivery: Delivers up to 700L/min max airflow, ideal for multi-tool setups, impact wrenches, sanders, spray guns and industrial pneumatic equipment.
● Belt-Driven Design for Reduced Wear: Belt-drive system lowers pump speed to 920R.P.M, reducing component stress and extending the pump’s lifespan.
● Robust Portable Design: Fitted with heavy-duty wheels and reinforced frame for stable transport and installation in workshop environments.
● Built-In Safety Protection: Features 10.0A overload protector and pressure relief valve to ensure safe, reliable operation under heavy industrial loads.
Expert Advice
● Daily Tank Drainage: Always drain condensed moisture from the 300L tank after each use to prevent internal corrosion and extend tank life.
● Electrical Safety: Install the compressor on a dedicated 300-400V three-phase power outlet rated for 9.0A; avoid extension cords to prevent voltage drop and motor damage.
● Ventilation & Cooling: Operate in a well-ventilated, dust-free area with adequate clearance around the pump and motor to prevent overheating during continuous use.
● Pre-Use Inspection: Check belt tension, hoses, fittings and connections for wear or leaks; verify pump oil level (1.0L capacity) is within the recommended range before starting.
● Regular Maintenance: Follow the maintenance schedule for oil checks and changes, belt tension adjustments, and filter cleaning to keep the pump running smoothly.
● Duty Cycle Compliance: This industrial model is designed for continuous heavy-duty use; follow the recommended maintenance intervals to ensure long-term performance.
Troubleshooting Guide
|
Problem |
Possible Cause |
Recommended Solution |
|
Compressor fails to start |
1. No power supply / faulty wiring or connection 2. Blown fuse or tripped circuit breaker 3. Overload protector activated 4. Defective pressure switch |
1. Verify power supply, inspect wiring and connections for damage 2. Reset circuit breaker or replace 9.0A rated fuse 3. Allow the motor to cool completely, then restart 4. Test and replace pressure switch if defective |
|
Motor runs but pump does not operate |
1. Loose or broken drive belt 2. Misaligned pulleys 3. Jammed pump mechanism |
1. Inspect belt tension and condition; adjust or replace if worn 2. Align motor and pump pulleys to correct position 3. Disassemble pump to clear debris or obstructions |
|
Pressure builds too slowly or fails to reach rated pressure |
1. Air leaks in hoses, fittings, check valve or tank 2. Worn piston rings, valves, or seals in the pump 3. Clogged air intake filter4. Pressure regulator set incorrectly |
1. Perform leak test with soapy water; tighten connections or replace faulty parts 2. Inspect and replace worn piston rings, reed valves, or seals 3. Clean or replace the air filter to restore airflow 4. Adjust regulator to the correct working pressure; check for regulator damage |
|
Excessive noise, vibration or unusual rattling |
1. Loose mounting bolts, fasteners, or pump components 2. Worn motor or pump bearings 3. Damaged or unbalanced flywheel/pulleys 4. Unit placed on an uneven or unstable surface |
1. Tighten all bolts and fasteners securely, including motor mounts and pump bolts 2. Inspect and replace worn bearings to eliminate noise and vibration 3. Service or replace damaged flywheel/pulleys if out of balance 4. Position the compressor on a flat, level, and stable surface; check rubber feet |
|
Motor overheats or shuts down prematurely |
1. Poor ventilation or blocked cooling vents 2. Continuous operation beyond rated duty cycle 3. Low oil level or degraded pump oil 4. Dirty or clogged cooling fins on the motor/pump |
1. Move the unit to a well-ventilated area; clear obstructions around vents 2. Follow the duty cycle guidelines; ensure proper cooling between runs 3. Check and top up pump oil to the correct level; replace oil if contaminated 4. Clean cooling fins to remove dust and debris, improving heat dissipation |
|
Air pressure drops significantly under load |
1. Undersized, kinked, or damaged air hoses 2. Incorrectly adjusted or faulty pressure regulator 3. Leaking check valve in the tank 4. Excessive air consumption from connected tools |
1. Replace hoses with the correct diameter, remove kinks, and repair leaks 2. Calibrate the pressure regulator to the required working pressure; replace if defective 3. Inspect, clean, or replace the check valve to maintain tank pressure 4. Verify the tool’s air consumption matches the compressor’s output capacity |
FAQs
▼ What size air compressor do I need?
The right compressor size depends primarily on the CFM (Cubic Feet per Minute) and pressure requirements of your pneumatic tools.
For heavy-duty industrial and workshop applications (e.g., multi-tool setups, impact wrenches, sanders, spray guns, and continuous pneumatic equipment use), the Cyclone Z-0.60EU 300L 6.0HP belt-driven model delivers the high-volume airflow needed for stable, uninterrupted performance.
▼ How often must I drain an air compressor?
Drain the tank daily after every use, or more frequently in humid environments. This prevents water buildup, internal corrosion, and rust, protecting the tank and downstream tools from contamination. Cyclone compressors are fitted with a convenient drain valve for quick and easy maintenance.
▼ What oil do I use in my air compressor?
Always use compressor-grade, non-detergent oil formulated for reciprocating air pumps. For this Cyclone model, use 1.0L of the recommended oil, and refer to the user manual for the exact viscosity grade required. Using the correct oil ensures optimal lubrication, reduces wear, and extends the pump’s service life.
▼ Can I use an extension cord with my compressor?
We strongly recommend avoiding extension cords whenever possible, as they can cause voltage drop, overheating, and permanent motor damage. If use is unavoidable, select a short, heavy-duty cord rated for the compressor’s full 9.0A current draw to minimize power loss.
▼ What size air hose should I use?
The correct hose size depends on your tool’s air consumption and the total hose length.
For high-volume industrial use with this Cyclone compressor, a 1/2" (13mm) or larger diameter hose is recommended to avoid pressure drop and maintain airflow efficiency, especially for multi-tool setups and longer runs.
Keywords:
Previous page
Next page
Previous page
Next page