Cyclone Z-0.25EU Belt-Driven Air Compressor Heavy-Duty Aluminium Alloy Monoblock Air Compressor for Workshop & Professional Use Professional Use Workshop & Professional Use Professional Workshop Applications
Engineered for high-volume performance and long-term durability, the Cyclone 200L 2.2kW (3.0HP) belt-driven air compressor features a robust aluminium alloy monoblock pump. This 220–240V unit delivers consistent, powerful airflow for demanding workshop, garage and trade tasks, combining industrial-grade reliability with a high-capacity tank for extended runtime. Backed by our in-house manufacturing and strict quality control, it’s the ideal workhorse for medium-to-heavy duty applications.ns.
Category:
Belt Driven Compressors-(Italy Style Mono block Air Pump)
Product Details
|
On the technical data plate we will state following information |
|
|
Name |
Aluminium Alloy MonoBlock Proessional Belt Driven Compressor |
|
Cyclone Model NO: |
Z-0.25EU |
|
Motor Peak Power |
2.2KW/3.0HP |
|
Input Voltage: |
220-240V/50HZ |
|
Max Air Delivery |
335L/min |
|
Air Delivery @ 60Psi |
316L/min |
|
Air Delivery @ 90Psi |
292L/min |
|
Motor Capacitors |
200vf+50Vf |
|
Pump Shaft Rated Speed |
1120 r.p.m |
|
Bore / Piston Size |
Dia.65mm*2 |
|
Stroke Length |
46mm |
|
Pump Flywheels |
300mm |
|
Motor pulley size |
120mm |
|
Pump Lubricate Oil capacity |
1.0L |
|
Rated Electric Current |
12.5A |
|
Overload Current Protector |
15.0A |
|
Startig Capacity |
160V,with 20M power calbe |
|
Max working pressure |
8Bar / 0.8Mpa / 116PSI |
|
Cut-In pressure |
6Bar / 0.6Mpa / 90PSI |
|
Tank Capacity |
Ce/ASME Qualified 200Lt Air Tank |
|
Noise (Lwa) |
94dB |
|
N.W/G.W |
103Kgs / 125Kgs. |
|
Packing Size(L+W*H) |
136*49*90CM |
|
Medium |
Nonlethal Compressed Air |
Key Features
● High-Performance Aluminium Alloy Monoblock Pump: 3.0HP belt-driven pump delivers powerful airflow with excellent heat dissipation and corrosion resistance, built for extended use.
● 200L CE/ASME Certified Air Tank: Oversized thick-gauge steel tank provides long continuous runtime, minimizing pressure drops during heavy use.
● High-Volume Airflow: Delivers up to 335L/min max airflow, suitable for impact wrenches, spray guns, sanders, and multi-tool workshop setups.
● Belt-Driven Design for Reduced Wear: Belt-drive system lowers pump speed to 1120R.P.M, reducing component stress and extending the pump’s service life.
● Portable Heavy-Duty Build: Fitted with large wheels and a reinforced handle for easy transport between workstations, ideal for both fixed workshop and mobile service use.
● Built-In Safety Protection: Features 15.0A overload protector and pressure relief valve to ensure safe, reliable operation under heavy loads.
Expert Advice
● Daily Tank Drainage: Always drain condensed moisture from the 200L tank after each use to prevent internal corrosion and extend tank life.
● Electrical Safety: Use a dedicated grounded power outlet rated for 12.5A; avoid long extension cords to prevent voltage drop and motor damage.
● Ventilation & Cooling: Operate in a well-ventilated area with adequate clearance around the motor and pump to prevent overheating during heavy use.
● Pre-Use Inspection: Check belt tension, hoses, fittings and connections for wear or leaks; verify pump oil level (1.0L capacity) is within the recommended range before starting.
● Regular Maintenance: Follow the maintenance schedule for oil checks and changes, belt tension adjustments, and filter cleaning to keep the pump running smoothly.
● Duty Cycle Compliance: Adhere to the rated duty cycle; allow sufficient cooling breaks between heavy continuous runs to protect the motor.
Troubleshooting Guide
|
Problem |
Possible Cause |
Recommended Solution |
|
Compressor fails to start |
1. No power supply / faulty plug, cable or socket 2. Blown fuse or tripped circuit breaker 3. Overload protector activated 4. Defective pressure switch |
1. Verify power supply, inspect plug, cable and socket for damage 2. Reset circuit breaker or replace 12.5A rated fuse 3. Allow the motor to cool completely, then restart 4. Test and replace pressure switch if defective |
|
Motor runs but pump does not operate |
1. Loose or broken drive belt 2. Misaligned pulleys 3. Jammed pump mechanism |
1. Inspect belt tension and condition; adjust or replace if worn 2. Align motor and pump pulleys to correct position 3. Disassemble pump to clear debris or obstructions |
|
Pressure builds too slowly or fails to reach rated pressure |
1. Air leaks in hoses, fittings, check valve or tank 2. Worn piston rings, valves, or seals in the pump 3. Clogged air intake filter 4. Pressure regulator set incorrectly |
1. Perform leak test with soapy water; tighten connections or replace faulty parts 2. Inspect and replace worn piston rings, reed valves, or seals 3. Clean or replace the air filter to restore airflow 4. Adjust regulator to the correct working pressure; check for regulator damage |
|
Excessive noise, vibration or unusual rattling |
1. Loose mounting bolts, fasteners, or pump components 2. Worn motor or pump bearings 3. Damaged or unbalanced flywheel/pulleys 4. Unit placed on an uneven or unstable surface |
1. Tighten all bolts and fasteners securely, including motor mounts and pump bolts 2. Inspect and replace worn bearings to eliminate noise and vibration 3. Service or replace damaged flywheel/pulleys if out of balance 4. Position the compressor on a flat, level, and stable surface; check rubber feet |
|
Motor overheats or shuts down prematurely |
1. Poor ventilation or blocked cooling vents 2. Continuous operation beyond the rated duty cycle 3. Low oil level or degraded pump oil 4. Dirty or clogged cooling fins on the motor/pump |
1. Move the unit to a well-ventilated area; clear obstructions around vents 2. Follow the duty cycle guidelines; allow sufficient cooling breaks between runs 3. Check and top up pump oil to the correct level; replace oil if contaminated 4. Clean cooling fins to remove dust and debris, improving heat dissipation |
|
Air pressure drops significantly under load |
1. Undersized, kinked, or damaged air hoses 2. Incorrectly adjusted or faulty pressure regulator 3. Leaking check valve in the tank 4. Excessive air consumption from connected tools |
1. Replace hoses with the correct diameter, remove kinks, and repair leaks 2. Calibrate the pressure regulator to the required working pressure; replace if defective 3. Inspect, clean, or replace the check valve to maintain tank pressure 4. Verify the tool’s air consumption matches the compressor’s output capacity |
FAQs
▼ What size air compressor do I need?
The right compressor size depends primarily on the CFM (Cubic Feet per Minute) and pressure requirements of your pneumatic tools.
For medium-to-heavy duty workshop and trade tasks (e.g., impact wrenches, spray guns, sanders, multi-tool setups), the Cyclone Z-0.25EU 200L 3.0HP belt-driven model delivers the high-volume airflow and long runtime needed for stable, continuous performance.
For lighter DIY tasks, a smaller model may be sufficient; for industrial use, choose a compressor with a higher CFM rating that exceeds your tool’s requirements by at least 20%.
▼ How often must I drain an air compressor?
Drain the tank daily after every use, or more frequently in humid environments. This prevents water buildup, internal corrosion, and rust, protecting the tank and downstream tools from contamination. Cyclone compressors are fitted with a convenient drain valve for quick and easy maintenance.
▼ What oil do I use in my air compressor?
Always use compressor-grade, non-detergent oil formulated for reciprocating air pumps. For this Cyclone model, use 1.0L of the recommended oil, and refer to the user manual for the exact viscosity grade required. Using the correct oil ensures optimal lubrication, reduces wear, and extends the motor’s service life.
▼ Can I use an extension cord with my compressor?
We strongly recommend avoiding extension cords whenever possible, as they can cause voltage drop, overheating, and permanent motor damage. If use is unavoidable, select a short, heavy-duty cord rated for the compressor’s full 12.5A current draw to minimize power loss.
▼ What size air hose should I use?
The correct hose size depends on your tool’s air consumption and the total hose length.
For high-volume use with this Cyclone compressor, a 1/2" (13mm) diameter hose is recommended to avoid pressure drop and maintain airflow efficiency, especially for longer runs or multi-tool setups.