Cyclone Z-0.25EU Aluminium Alloy MonoBlock Proessional Belt Driven Compressor High-Efficiency Professional Belt Driven Compressor with Aluminium Alloy MonoBlock Pump
Engineered for professional use and reliable performance in various working environments, the Cyclone 100L 3.0HP (2.2kW) aluminium alloy monoblock professional belt driven compressor features a high-quality electric motor and durable aluminium alloy monoblock pump, delivering stable airflow and consistent pressure. This unit is ideal for professional workshops, industrial auxiliary operations, and various pneumatic tool applications, providing reliable compressed air supply to meet daily professional work needs. Backed by strict quality control and heavy-duty structural design, it ensures durable and stable operation even in long-term working conditions.
Category:
Belt Driven Compressors-(Italy Style Mono block Air Pump)
Product Details
|
On the technical data plate we will state following information |
|
|
Name |
Aluminium Alloy MonoBlock Proessional Belt Driven Compressor |
|
Cyclone Model NO: |
Z-0.25EU |
|
Motor Peak Power |
2.2KW/3.0HP |
|
Input Voltage: |
220-240V/50HZ |
|
Max Air Delivery |
335L/min |
|
Air Delivery @ 60Psi |
316L/min |
|
Air Delivery @ 90Psi |
292L/min |
|
Motor Capacitors |
200vf+50Vf |
|
Pump Shaft Rated Speed |
1120 r.p.m |
|
Bore / Piston Size |
Dia.65mm*2 |
|
Stroke Length |
46mm |
|
Pump Flywheels |
300mm |
|
Motor pulley size |
120mm |
|
Pump Lubricate Oil capacity |
1.0L |
|
Rated Electric Current |
12.5A |
|
Overload Current Protector |
15.0A |
|
Startig Capacity |
160V,with 20M power calbe |
|
Max working pressure |
8Bar / 0.8Mpa / 116PSI |
|
Cut-In pressure |
6Bar / 0.6Mpa / 90PSI |
|
Tank Capacity |
Ce/ASME Qualified 100Lt Air Tank |
|
Noise (Lwa) |
94dB |
|
N.W/G.W |
78Kgs / 88Kgs. |
|
Packing Size(L+W*H) |
108*38*76CM |
|
Medium |
Nonlethal Compressed Air |
Key Features
● Efficient Electric Motor: Equipped with a high-performance electric motor, delivering 2.2KW (3.0HP) peak power, with 220-240V/50HZ input voltage, providing stable and efficient power for professional operations.
● Stable Air Delivery Performance: Max air delivery of 335L/min, with 316L/min @ 60Psi and 292L/min @ 90Psi, meeting the airflow demands of various professional pneumatic tools and auxiliary operations.
● Aluminium Alloy MonoBlock Pump: Adopts durable aluminium alloy monoblock pump design, with Dia.65mm*2 bore/piston size and 46mm stroke length, ensuring efficient air compression and long service life.
● 100L Large-Capacity Air Tank: CE/ASME qualified thick-gauge steel tank, ensuring safe and stable pressure retention, reducing frequent startup of the motor and extending service life.
● Reliable Electrical Protection: Equipped with 200vf+50Vf motor capacitors, 12.5A rated electric current, and 15.0A overload current protector, effectively preventing electrical faults and ensuring safe operation.
● Convenient Starting: 160V starting capacity with 20M power cable, allowing flexible use in different working scenarios and ensuring reliable startup even in unstable voltage environments.
● Stable Operation: 300mm pump flywheel, 120mm motor pulley, and 1120 r.p.m pump shaft rated speed, ensuring smooth operation, low vibration and stable airflow output; 94dB noise level, balancing performance and user comfort.
● Reliable Lubrication: 1.0L pump lubricate oil capacity, effectively reducing wear of internal components and extending the service life of the compressor.
Expert Advice
● Daily Tank Drainage: Always drain condensed moisture from the 100L tank after each use, or more frequently in humid environments, to prevent internal corrosion, water contamination and ensure compressed air quality.
● Electrical Safety: Ensure the input voltage is 220-240V/50HZ before use; check the 20M power cable for damage regularly, and avoid using the compressor in wet environments to prevent electric shock.
● Lubrication Maintenance: Check the pump lubricate oil level (1.0L capacity) before each startup; replace oil according to the maintenance schedule to ensure good lubrication of the air pump.
● Motor Protection: Do not overload the compressor beyond the 12.5A rated electric current; the 15.0A overload current protector will trigger if overloaded, please cut off the power and check the cause before restarting.
● Starting Attention: Ensure the starting capacity is within 160V; if the voltage is unstable, avoid starting the compressor to prevent motor damage. The 20M power cable allows flexible placement, but avoid dragging or damaging the cable.
● Component Inspection: Regularly check the pump flywheel (300mm), motor pulley (120mm), and drive belt for wear or looseness; adjust or replace in time to ensure normal power transmission.
● Pump Maintenance: Regularly inspect the aluminium alloy monoblock pump, bore (Dia.65mm*2) and piston stroke (46mm) for wear; clean or replace components as needed to maintain optimal air delivery performance.
Troubleshooting Guide
|
Problem |
Possible Cause |
Recommended Solution |
|
Compressor fails to start |
1. Input voltage not 220-240V/50HZ 2. Damaged 20M power cable 3. Faulty motor capacitors (200vf+50Vf) 4. Overload current protector (15.0A) triggered5. Voltage below 160V (starting capacity) |
1. Ensure input voltage is 220-240V/50HZ 2. Replace damaged power cable 3. Inspect and replace faulty motor capacitors 4. Reset the overload current protector and check for overload 5. Wait for voltage to rise above 160V before starting |
|
Motor runs but pump does not operate |
1. Loose or broken drive belt 2. Misaligned motor pulley (120mm) and pump flywheel (300mm) 3. Jammed air pump piston (Dia.65mm*2) or mechanism |
1. Adjust, tighten or replace the drive belt 2. Align the motor pulley and pump flywheel 3. Disassemble the pump to remove debris and check piston movement |
|
Pressure builds too slowly or fails to reach 8Bar |
1. Air leaks in hoses, fittings or check valve 2. Worn air pump piston (Dia.65mm*2) or piston rings 3. Clogged air intake filter 4. Pump shaft speed lower than 1120 r.p.m |
1. Perform leak test and repair leaks 2. Inspect and replace worn piston or piston rings 3. Clean or replace the air intake filter 4. Check motor operation to ensure pump shaft runs at 1120 r.p.m |
|
Excessive noise, vibration or unusual sound |
1. Loose mounting bolts or components 2. Worn bearings in motor or air pump 3. Unbalanced 300mm pump flywheel 4. Uneven placement surface |
1. Tighten all bolts and fasteners securely 2. Inspect and replace worn bearings 3. Service or replace the unbalanced flywheel 4. Place the compressor on a flat, stable surface |
|
Overload current protector triggers frequently |
1. Electrical load exceeds 12.5A rated current 2. Input voltage unstable or too low 3. Motor capacitors (200vf+50Vf) faulty 4. Pump mechanism jammed |
1. Reduce the number of connected tools to lower load 2. Ensure input voltage is stable at 220-240V 3. Inspect and replace faulty motor capacitors 4. Disassemble and repair the jammed pump mechanism |
|
Air pressure drops significantly under load |
1. Undersized or damaged air hoses 2. Faulty pressure regulator 3. Leaking check valve 4. Total air consumption exceeds 335L/min |
1. Replace with appropriate diameter hoses and repair damage 2. Calibrate or replace the pressure regulator 3. Inspect, clean or replace the check valve 4. Reduce the number of connected tools to ensure consumption ≤ 335L/min |
FAQs
▼ What size air compressor do I need?
The right compressor depends on your CFM and pressure requirements. For professional workshops, industrial auxiliary operations and daily pneumatic tool use, the Cyclone Z-0.25EU 100L 3.0HP electric model provides sufficient power (2.2KW) and stable air delivery (max 335L/min).
▼ How often must I drain an air compressor?
Drain the 100L tank daily after every use, or more frequently in humid environments, to prevent internal corrosion and water contamination.
▼ What oil do I use in my air compressor?
Use professional compressor-grade non-detergent oil for the air pump, with a capacity of 1.0L; refer to the product manual for specific oil specifications.
▼ Can I use this compressor in wet environments?
No. This is an electric compressor, and using it in wet environments may cause electric shock. Always operate in a dry, well-ventilated area.
▼ What should I do if the overload current protector triggers?
First, cut off the power supply, check if the electrical load exceeds 12.5A or if the input voltage is unstable, eliminate the fault, then reset the overload current protector and restart the compressor.
Keywords:
Previous page
Next page
Previous page
Next page