Cyclone ZB2024 Direct Drive Air CompressorDurable Portable Compressor for Home, Garage & Professional Workshops
Engineered for durability and portability, the Cyclone 24L 1.45kW (2HP) direct drive air compressor is a trusted choice for DIY enthusiasts and trade professionals alike. Built with premium thick steel tanks and quality components, this 230V unit delivers stable, efficient performance for inflating, air blowing, pneumatic tools, spray painting, and everyday workshop tasks. Backed by our in-house manufacturing and strict quality control, it’s the reliable all-rounder for your home, garage or workshop.
Category:
Direct Link Air Compressors
Product Details
|
On the technical data plate we will state following information |
|
|
Name |
Oil-Lubricated Professional Direct Driven Compressor |
|
Cyclone Model NO: |
ZB2024EU |
|
Motor Peak Power: |
1.5KW/2.0HP |
|
Input Voltage: |
220-240V/50HZ |
|
Max Air Delivery |
188L/min |
|
Air Delivery@40Psi |
165L/min |
|
Air Delivery@90Psi |
152L/min |
|
Motor Capacitor |
35VF |
|
Pump Shaft Rated Speed |
2850r.p.m |
|
Bore/Piston Size |
Dia.47mm*1 |
|
Stroke Length |
38mm |
|
Pump Flywheels |
N/M |
|
Motor pulley size |
N/M |
|
Pump Lubricate Oil capacity |
0.25L |
|
Rated Electric Current |
6.0A |
|
Overload Current Protector |
8.0A |
|
Startig Capacity |
185V,with 20M power calbe |
|
Max working pressure |
8Bar /0.8Mpa/116PSI |
|
Cut-In pressure |
6Bar/0.6Mpa/90PS1 |
|
Tank Capacity |
Ce/ASME Qualified 24Lt Air Tank |
|
Noise (Lwa) |
92dB |
|
N.W/G.W |
25.0Kgs/27.0kgs |
|
Packing Size(L+W*H) |
61*27.5*59CM |
|
Medium |
Nonlethal Compressed Air |
Key Features
● Oil-Lubricated Direct Drive Motor: Delivers stable, reliable performance with reduced wear, extending the compressor’s service life.
● 24L Heavy-Duty Air Tank: Compact yet robust tank suitable for home, garage, and light workshop applications.
● High Efficiency Airflow: Delivers 109 L/min airflow at optimal efficiency for consistent pneumatic tool performance.
● Integrated Pressure Regulator & Gauges: Allows precise pressure control and real-time monitoring for different tasks.
● Portable & Space-Saving Design: Equipped with wheels and a handle for easy transport and convenient storage.
● Built for Durability: Features quality components and a reinforced frame for long-term daily use.
Expert Advice
● Daily Tank Drainage: Always drain moisture from the tank after use to prevent internal corrosion, contamination, and maintain air quality.
● Electrical Safety: Avoid using long extension cords, as they can cause voltage drop, overheating, and potential motor damage. Use a dedicated power outlet.
● Ventilation & Cooling: Operate the compressor in a well-ventilated area to prevent overheating and ensure optimal motor performance.
● Pre-Use Check: Inspect hoses, fittings, and connections for leaks or damage before each use to ensure safe and efficient operation.
● Regular Maintenance: Follow the maintenance schedule for oil checks and replacements to keep the motor running smoothly.
Troubleshooting Guide
|
Problem |
Possible Cause |
Recommended Solution |
|
Compressor fails to start |
1. No power supply / faulty plug, cable or socket 2. Blown fuse or tripped circuit breaker 3. Overload protection activated due to overheating 4. Defective pressure switch |
1. Verify power supply, inspect plug, cable and socket for damage 2. Reset circuit breaker or replace the fuse with the correct rating 3. Allow the motor to cool completely, then restart the unit 4. Test and replace the pressure switch if it fails to activate properly |
|
Motor hums but does not run |
1. Low or unstable incoming voltage 2. Jammed or seized pump mechanism 3. Defective motor capacitor 4. Mechanical binding in the pump assembly |
1. Confirm the power supply meets the rated voltage; eliminate long extension cords 2. Disassemble the pump to remove debris or obstructions blocking the piston 3. Test and replace the capacitor if it shows signs of failure 4. Lubricate moving parts or repair/replace damaged pump components |
|
Pressure builds too slowly or fails to reach rated pressure |
1. Air leaks in hoses, fittings, check valve, or tank 2. Worn piston rings, valves, or seals in the pump 3. Clogged air intake filter 4. Pressure regulator set incorrectly |
1. Perform a leak test with soapy water; tighten connections or replace faulty parts 2. Inspect and replace worn piston rings, reed valves, or seals 3. Clean or replace the air filter to restore airflow 4. Adjust the regulator to the correct working pressure; check for regulator damage |
|
Excessive noise, vibration or unusual rattling |
1. Loose mounting bolts, fasteners, or pump components 2. Worn motor or pump bearings 3. Damaged or unbalanced crankshaft 4. Unit placed on an uneven or unstable surface |
1. Tighten all bolts and fasteners securely, including motor mounts and pump bolts 2. Inspect and replace worn bearings to eliminate noise and vibration 3. Service or replace the crankshaft if it is damaged or out of balance 4. Position the compressor on a flat, level, and stable surface; check rubber feet |
|
Motor overheats or shuts down prematurely |
1. Poor ventilation or blocked cooling vents 2. Continuous operation beyond the rated duty cycle 3. Low oil level or degraded pump oil 4. Dirty or clogged cooling fins on the motor/pump |
1. Move the unit to a well-ventilated area; clear obstructions around vents 2. Follow the duty cycle guidelines; allow sufficient cooling breaks between runs 3. Check and top up pump oil to the correct level; replace oil if contaminated 4. Clean cooling fins to remove dust and debris, improving heat dissipation |
|
Air pressure drops significantly under load |
1. Undersized, kinked, or damaged air hoses 2. Incorrectly adjusted or faulty pressure regulator 3. Leaking check valve in the tank 4. Excessive air consumption from connected tools |
1. Replace hoses with the correct diameter, remove kinks, and repair leaks 2. Calibrate the pressure regulator to the required working pressure; replace if defective 3. Inspect, clean, or replace the check valve to maintain tank pressure 4. Verify the tool’s air consumption matches the compressor’s output capacity |
FAQs
▼ What size air compressor do I need?
The right compressor size depends primarily on the CFM (Cubic Feet per Minute) and pressure requirements of your pneumatic tools.
For light-duty tasks (e.g., tire inflation, brad nailers, light stapling), a compact 24L model like this Cyclone unit is fully sufficient.
For more demanding tools (e.g., impact wrenches, spray guns, sanders), choose a compressor with a higher CFM rating that exceeds your tool’s requirements by at least 20% to ensure stable performance.
▼ How often must I drain an air compressor?
Drain the tank daily after every use, or more frequently in humid environments. This prevents water buildup, internal corrosion, and rust, protecting the tank and downstream tools from contamination. Cyclone compressors are fitted with a convenient drain valve for quick and easy maintenance.
▼ What oil do I use in my air compressor?
Always use compressor-grade, non-detergent oil formulated for reciprocating air pumps. For this Cyclone model, refer to the user manual for the exact viscosity grade required. Using the correct oil ensures optimal lubrication, reduces wear, and extends the motor’s service life.
▼ Can I use an extension cord with my compressor?
We strongly recommend avoiding extension cords whenever possible, as they can cause voltage drop, overheating, and permanent motor damage. If use is unavoidable, select a short, heavy-duty cord rated for the compressor’s full current draw to minimize power loss.
▼ What size air hose should I use?
The correct hose size depends on your tool’s air consumption and the total hose length.
For most light-to-medium workshop tasks with this Cyclone compressor, a 3/8" (10mm) diameter hose is ideal.
For longer hose runs or higher-demand tools, use a larger diameter hose to avoid pressure drop and maintain airflow efficiency.
Keywords:
Previous page
Next page
Previous page
Next page